    Heating & cooling

    Heating and cooling an older brick veneer home

    Heating and cooling choices for post-war and 1970s brick veneer homes in Altona, Laverton and Hoppers Crossing, where draughts and old ducts change the advice.

    6 min readPublished 9 October 2026
    Daikin wall-mounted split system on a timber-lined wall under a corrugated iron ceiling

    The key points

    • Fix the envelope first: ceiling insulation and draughts change the size and number of units the house needs.
    • Check any open-flued gas heater before sealing vents or draughts.
    • Wall splits suit most older brick veneers. Ducted reverse-cycle works where the roof space allows.
    • Old under-floor gas ducts rarely suit cooling, so a move to reverse-cycle usually means ceiling ducts or wall units.
    • An older switchboard may need work before new circuits go in, so have it checked at the same visit.

    How these homes were built

    Brick veneer means a timber-framed house with a single skin of brick outside, a cavity between the two and plasterboard inside. Through the post-war decades and the 1970s it became a standard way to build across Melbourne's west. The Hobsons Bay planning scheme notes that post-war industrial and residential growth transformed Altona and Laverton, and much of Hoppers Crossing dates from the 1970s and 1980s.

    The brick looks solid but does little for comfort. Many homes of that era were built with little or no wall insulation, thin ceiling batts that have since settled or been disturbed, single-glazed timber or aluminium windows, and timber floors over a ventilated subfloor. Altona's special character areas exist to protect intact post-war brick and weatherboard homes from exactly that period.

    Start with insulation and draughts

    Before choosing a system, look at what's letting heat in and out. A ceiling bare in patches, a gap under every door and floorboards breathing cold subfloor air can make a well-sized unit seem too small. Fixing them often lets a smaller system do the job, and every system works better in a tighter house.

    Work in the ceiling needs care around old wiring and downlights, and insulation shouldn't be packed over downlights or their transformers. Energy Safe Victoria advises owners of houses over 30 years old to have their wiring checked by a licensed electrician, and that's worth doing before anyone starts crawling through the roof.

    • Ceiling insulation: thickness and coverage, checked from the manhole
    • Draughts: windows, external doors, unused fireplaces and wall vents
    • Floors: gaps between boards and under skirting on homes with a subfloor
    • Windows: heavy curtains with pelmets or close-fitting blinds on the worst ones
    • Shade: external blinds or awnings on west-facing glass

    Check the gas heater before sealing anything

    Many of these homes still have a gas wall heater in the lounge or a ducted gas heater under the floor, and many have permanent wall vents. Some of those vents are there to give gas appliances the air they need.

    Energy Safe Victoria warns that renovating or weather-sealing a home that still has an open-flued gas heater may change the ventilation needed to clear carbon monoxide, which could trap dangerous CO inside, and it says open-flued heaters spill CO more easily than other types. Before blocking vents, replacing windows or draught-proofing, have a licensed gasfitter check the heater and its ventilation.

    If you're retiring the gas heater, a licensed gasfitter should disconnect and cap it. The vents it relied on can then be reviewed.

    Which system suits

    Wall-hung split systems suit most older brick veneers. They need no roof space, each room is controlled on its own, and a split in the living area plus one or two in bedrooms covers what most households use. Victorians typically use more energy for heating than cooling, and Laverton's July mean minimum is 5.2 °C, so choose units on their Cold zone heating performance, not just the cooling figure.

    Ducted reverse-cycle can work, but these homes often have low-pitched tiled roofs with tight access, which makes placing an indoor unit and running ducts well harder. Have the roof space looked at before you settle on the idea. A multi-head split, with one outdoor unit feeding several rooms, is a middle path where there's only one good spot outside.

    Wide side setbacks, common on post-war blocks in Altona, usually leave room for outdoor units along the side of the house, out of sight of the street. In a special character area, ask your council whether anything visible from the street needs a permit.

    Old under-floor ducts

    A 1970s or 1980s gas ducted heater often sits under the house, with floor outlets in each room and ducts through the subfloor. After decades down there, those ducts may be uninsulated, crushed, disconnected or chewed.

    Floor outlets are good for heating, but cold air pools on the floor and doesn't spread, so under-floor ducts rarely suit reverse-cycle cooling. YourHome says ducts should be insulated to at least R1.5 with sealed joints. A move from gas ducted to reverse-cycle usually means new ceiling ducts or wall units, with the old floor outlets sealed.

    Owner-occupiers aren't required to switch gas space heating to electric. If you're keeping the gas heater for now, a duct check is still worthwhile, because a leaking subfloor duct heats the ground under the house instead of the bedrooms.

    The switchboard and wiring

    Older homes often still have the original switchboard, sometimes with ceramic fuses and no safety switches, or a board added to over the years with no spare space. A new reverse-cycle system needs its own circuit and a lockable isolating switch next to the outdoor unit, so the board needs room for it.

    Energy Safe Victoria notes that the Wiring Rules require additional safety switch protection when an existing installation is altered, and a replacement switchboard needs safety switches on every final sub-circuit. If the board is an old fuse board, upgrading it is often the cleanest path. That's prescribed work, and the power can't go back on to the new board until a licensed electrical inspector has inspected it.

    Old switchboards can also contain asbestos. WorkSafe Victoria lists switchboards and their backing boards as a typical location for asbestos in buildings built or renovated before the late 1980s, so leave the board alone and let the electrician assess it.

    A sensible order of work

    For most older brick veneers, a sensible order is to have the switchboard and wiring checked, get any gas heater assessed, fix the worst insulation gaps and draughts, then size the heating and cooling for the house as it will be. Doing it the other way round tends to buy more system than the house needs.

    Look at existing units at the same time. The Victorian Government says a reverse-cycle system more than 15 years old will typically use more than three times the energy of a modern one, so an early split in the lounge is worth reassessing while the rest of the plan comes together.

    Common questions

    No. The brick is a weather skin. Most of the insulating work is done by the ceiling, walls and windows, and in older brick veneers those are often the weak points.

    Quick answers

    More in the Help centre

    Sources for this guide

    15 sources, with the date each was checked
    1. 1.Victorian Government, Hobsons Bay Planning Scheme (PDF snapshot, last updated by VC292 on 11/09/2025): The heritage places of Hobsons Bay reflect the key themes that have shaped the development of the city since the establishment of Williamstown in the 1840s as the first port of Melbourne, through the development of… Accessed 30 September 2026.
    2. 2.Energy Safe Victoria: Old switchboards, particularly those without a safety switch Old power switches or power points, particularly broken ones Flickering lights Sparks from switchboards, switches or power points. If your house is over 30… Accessed 30 September 2026.
    3. 3.Energy Safe Victoria: If you have renovated or weather-sealed your home and kept your open-flued gas heater, you may have inadvertently altered the ventilation your home needs to clear carbon monoxide from your gas heater. This might be… Accessed 30 September 2026.
    4. 4.Energy Safe Victoria: Open-flued heaters can spill carbon monoxide more easily than other types of heaters, making them more dangerous. Accessed 30 September 2026.
    5. 5.Department of Energy, Environment and Climate Action (energy.vic.gov.au), page last updated 14/04/25: Victorians typically use more energy for heating than cooling, so look for a unit with a higher heating efficiency. Accessed 30 September 2026.
    6. 6.Bureau of Meteorology: Mean minimum temperature (°C) 14.0 14.4 12.7 10.0 7.8 5.9 5.2 5.7 6.8 8.4 10.3 12.2 9.5 81 1943 2026 Accessed 30 September 2026.
    7. 7.Commonwealth of Australia (2019), hosted on energyrating.gov.au: In the Cold zone the heating function is used much more than the cooling function and the performance of the air conditioner in frosting conditions (below 5.5°C) is critical in determining the overall performance of the… Accessed 30 September 2026.
    8. 8.YourHome (Australian Government): Ducts must be well insulated, to at least R1.5, and joints sealed to prevent condensation and leakage. The roof should have reflective foil insulation installed and be vented to dispel hot air. Zoned systems cool only… Accessed 30 September 2026.
    9. 9.Department of Energy, Environment and Climate Action (Victoria): From 1 March 2027, if a gas hot water appliance breaks and cannot be repaired, it must be replaced with an electric alternative. No requirement to upgrade gas space heating or stovetop gas cooking to electric, however… Accessed 30 September 2026.
    10. 10.Access Canberra Electrical Inspections (ACT Government), Electrical Fact Sheet, updated September 2019: Air-conditioning and heat pump systems incorporating a compressor shall be provided with an isolating switch (lockable) in accordance with Clause 2.3.2.2, installed adjacent to but not on the unit, which isolates all… Accessed 30 September 2026.
    11. 11.Energy Safe Victoria: Clause 2.6.3.2.5 of the Wiring Rules states: Additional protection by RCDs shall be provided in existing electrical installations where alterations or a switchboard replacement is completed. Accessed 30 September 2026.
    12. 12.Energy Safe Victoria: If a switchboard is required to be replaced then as per clause 2.6.3.2.5 (Alterations to installations and replacement of switchboards) of AS/NZS 3000: RCD’s are required on all final sub-circuits. Accessed 30 September 2026.
    13. 13.Energy Safe Victoria: The electrician has eight business days after the work is completed to have that work inspected by a licensed electrical inspector (LEI). If an electrician replaces a main switchboard at a property, power cannot go back… Accessed 30 September 2026.
    14. 14.WorkSafe Victoria: A person who has management or control of a workplace, and employers or self-employed persons and employees should be aware of the typical uses and applications of ACMs, particularly in buildings constructed or… Accessed 30 September 2026.
    15. 15.Solar Victoria (updated 2 October 2025): A system that is more than 15 years old for example will typically use more than three times the amount of energy than a modern reverse-cycle air conditioner. Accessed 30 September 2026.

    Planning advice for homeowners. Installation requirements depend on the property and equipment. Where this guide refers to Victorian safety or rental rules, use the linked official guidance for the current requirements.