    Heating & cooling

    Heating and cooling a double-storey home

    Why the bedrooms upstairs bake while the living areas stay cool, and how zoning by level, two systems or splits upstairs can even out a double storey.

    7 min readPublished 9 October 2026
    Total Comfort technician checking a ceiling return-air grille

    The key points

    • Upstairs sits under the hot roof and collects rising warm air, so double storeys run warm upstairs in summer and cool downstairs in winter.
    • One ducted system can serve both floors if each level is its own zone with its own temperature sensor, and the return air is planned for both.
    • Two smaller systems, one per floor, give each level its own capacity and controls, at the cost of a second outdoor unit and circuit.
    • Wall splits in the upstairs bedrooms are often the simplest fix when an existing system copes downstairs but loses the bedrooms on hot nights.

    Why the two floors never agree

    Many double-storey homes in Point Cook, Werribee, Wyndham Vale and Tarneit follow a similar plan: an open kitchen, meals and family area downstairs, with the bedrooms, a rumpus and a bathroom or two upstairs. The floors are used at different times and behave differently, so one setting rarely suits both.

    Upstairs sits right under the roof. On a hot northerly afternoon the roof space gets much hotter than the outside air and keeps pushing heat down through the ceiling well into the evening, just as everyone heads to bed. Warm air from downstairs drifts up the stairwell and adds to it. The Bureau of Meteorology's Laverton station averages 27 days a year at or above 30 °C, and those are the nights the bedrooms stay stuffy.

    Winter turns it around. Downstairs sits on a cool slab, often with wide sliding doors to the yard, and the heat you put into the living area rises up the stairs. The landing ends up the warmest spot in the house while the family room feels cool near the floor. An open stairwell or void links the floors, so whatever you install has to work with that air movement, not against it.

    Cut the heat load before adding equipment

    Part of the imbalance comes from the building, not the equipment, and that part is usually cheaper to fix first. A bedroom with a large west-facing window and no eaves can take on more heat in an afternoon than a well-shaded room twice its size.

    Insulation matters most in the ceiling over the upper floor, because that is the one under the hot roof. If you can look from the manhole safely, check it is there, even and not pushed aside by past trades. The ceiling between the two floors matters far less.

    Then size equipment for what is left. A room needs less capacity once the sun is kept off its glass.

    • Ceiling insulation over the upper floor, present and evenly laid
    • Shading on west and north-facing bedroom windows
    • Whether the stairwell can be closed off with a door, if the layout allows
    • Which rooms are worst, and at what time of day

    One ducted system, zoned by level

    A single ducted reverse-cycle system can serve both floors well if it is zoned and sized for the whole house. The Victorian Government recommends zones for ducted systems so each area can be heated or cooled on its own, and suggests 1.1 to 1.4 kW of heating output for every 10 m² covered, depending on the home. In a double storey the natural split is one zone, or a group of zones, for each level.

    What decides whether it works is where the temperature is read. If one sensor in a downstairs hallway runs everything, the system backs off while the bedrooms are still hot on a summer evening. With a sensor in each zone, the upstairs can run cooler than the living areas without one floor overriding the other. Return air matters too: a single return on one floor mostly draws that floor's air, which is why many two-level systems have a return on each level.

    The hard part in a finished home is getting ducts downstairs. The indoor unit usually sits in the roof above the upper floor, so ducts to the ground floor have to pass between floors, through a cupboard or inside a bulkhead. YourHome says ducts should be insulated to at least R1.5 with sealed joints, and long runs squeezed through tight spaces are where crushed or poorly joined ducts lose capacity. Zoning moves air; it doesn't add capacity, so size the unit for the times both floors are in use.

    Two systems: one for each floor

    Larger homes, and homes where both floors are busy at the same time, often do better with two smaller systems: one ducted unit for the bedrooms and another for the living areas, or ducted upstairs with wall splits downstairs. Each level gets its own capacity, controller and sensor, so there is no tug of war over one thermostat.

    It also spreads the risk. If one system fails in January, half the house still has cooling, and a smaller unit matched to fewer rooms runs at a steady low speed, which suits bedrooms overnight.

    The costs are real: two outdoor units to place, two systems to service and two circuits at the switchboard. Energy Safe Victoria says a manufacturer's requirement for a dedicated circuit or safety switch must be followed, and the original board in an estate home may not have the room for a second large system. Check that at the quote stage, not on installation day.

    Adding splits to the upstairs bedrooms

    Plenty of estate homes came with gas ducted heating and no cooling, or with a ducted system that copes downstairs but loses the bedrooms on hot nights. Wall splits in the upstairs bedrooms are often the most practical answer. They cool the rooms where people sleep, run quietly at low speed and leave the existing system to look after the rest of the house.

    Upstairs installs raise their own questions. The outdoor unit can sit on a wall bracket close to the room, or on the ground with a longer pipe run down the wall. Ground level is easier to service and keeps compressor noise away from bedroom windows, but the pipe route needs to be neat and protected. Each indoor head also needs a drain with a proper fall, which is simple on an external wall and harder on an internal one.

    A multi-head system runs several upstairs heads from one outdoor unit, which saves wall and ground space outside. The trade-off is that every head relies on that one unit. If noise matters, the Zoned Energy Rating Label gives split systems separate indoor and outdoor noise ratings, so compare those for bedroom heads.

    Running a two-level home through the year

    In summer, start cooling the bedrooms before they soak up the afternoon heat rather than at bedtime. Lower the blinds on the west side from early afternoon and close the doors of rooms nobody is using. The Victorian Government suggests 24 to 26 °C for cooling and 18 to 20 °C for heating living areas, and says each degree beyond that adds around 10% to running costs.

    In winter, heat the living areas through the evening and the bedrooms for a while before bed. Because warm air rises, the upstairs zone can usually be set a little lower than downstairs and still feel comfortable. Victorians typically use more energy for heating than cooling, and Laverton's July mean minimum is 5.2 °C, so winter habits make the bigger difference to the bills.

    What to sort out before you get quotes

    A useful quote for a double storey starts with how the house is used, not just its floor area. Note which rooms are used together and when, and which rooms are hardest to keep comfortable in each season. Ask each installer to explain where the temperature will be read on each level and where the return air goes.

    More than one licence is involved. In Victoria, refrigerated air-conditioning work is a class of plumbing work regulated by the Building and Plumbing Commission, and installing a system needs a Refrigerant Handling Licence. The circuits are electrical work: Energy Safe Victoria lists air conditioning as non-prescribed work, so the electrician completes a Certificate of Electrical Safety and must give you a copy within 30 days.

    • A sketch of each floor with room uses and the times they're occupied
    • The worst rooms in summer and in winter
    • Make, model and age of any existing heating or cooling
    • A photo of the switchboard, taken without opening any covers
    • Possible outdoor unit spots, ideally at ground level and away from bedroom windows

    Common questions

    Often the temperature is read downstairs or in a hallway, so the system backs off before the bedrooms cool. A zone for each level with its own sensor, a return air on each floor or a split upstairs are the usual fixes, once the filter and ducts are checked.

    Quick answers

    More in the Help centre

    Sources for this guide

    10 sources, with the date each was checked
    1. 1.Bureau of Meteorology: Mean number of days ≥ 30 °C 6.9 6.0 4.5 0.7 0.0 0.0 0.0 0.0 0.1 0.9 2.8 5.1 27.0 82 1943 2026 Mean number of days ≥ 35 °C 3.6 2.4 0.9 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.5 1.9 9.4 Accessed 30 September 2026.
    2. 2.Bureau of Meteorology (article issued 3 August 2026): To the north lies Australia's hot, dry interior, while to the south stretches the cold Southern Ocean. ... Warm northerly winds arrive first, bringing higher temperatures and clear skies. Then, as a cold front moves in… Accessed 30 September 2026.
    3. 3.Department of Energy, Environment and Climate Action (energy.vic.gov.au), page last updated 14/04/25: We recommend providing 1.1 to 1.4kW of heating output for every 10m² of your home covered by a ducted system, depending on the individual characteristics of your home. ... We recommend zones for your ducted system, as… Accessed 30 September 2026.
    4. 4.YourHome (Australian Government): Ducts must be well insulated, to at least R1.5, and joints sealed to prevent condensation and leakage. The roof should have reflective foil insulation installed and be vented to dispel hot air. Zoned systems cool only… Accessed 30 September 2026.
    5. 5.Energy Safe Victoria: This means that if the manufacturer’s specifications require an air conditioner to be installed on a dedicated circuit or protected by a residual current device then they must be adhered to. Accessed 30 September 2026.
    6. 6.Energy Rating (GEMS Regulator / DCCEEW): On the right of the label after the stars, is the estimated annual energy use or power input in kilowatt hours (kWh) displaying cooling in blue (top number) and heating in red for each climate zone. ... Products are… Accessed 30 September 2026.
    7. 7.Solar Victoria (updated 20 November 2025): To heat a room, try setting the temperature between 18°C to 20°C. Every 1°C higher will add around 10% to your heating bill. Set your air conditioner thermostat for cooling between 24°C and 26°C for living areas – every… Accessed 30 September 2026.
    8. 8.Building and Plumbing Commission (Victorian Building Authority, trading as the Building and Plumbing Commission): Under Part 4 of the Plumbing Regulations 2018, Refrigerated Air-conditioning work is: The construction, installation, replacement, repair, alteration, maintenance, testing or commissioning of refrigerated… Accessed 30 September 2026.
    9. 9.Australian Refrigeration Council (ARC): A Refrigerant Handling Licence must be held by any person who carries out work in relation to refrigeration and air conditioning (RAC) equipment. Carrying out work in relation to RAC equipment means to do anything with… Accessed 30 September 2026.
    10. 10.Energy Safe Victoria: 'Prescribed' certificates are for electrical installation work that requires inspection by a Licensed Electrical inspector. This includes (but is not limited to): Consumer mains cables, main switchboard, meter box and… Accessed 30 September 2026.

    Planning advice for homeowners. Installation requirements depend on the property and equipment. Where this guide refers to Victorian safety or rental rules, use the linked official guidance for the current requirements.