    Why has one zone stopped working on my ducted system?

    Updated 9 October 2026

    The short answer
    When one zone gets no air but the rest work, check the controller first: the zone may be switched off, on a schedule or, with temperature-controlled zones, already at its set temperature. If the settings are right, the usual faults are a failed damper motor, a damaged control cable or a duct that has come off in the roof space. Those need someone in the roof.

    Rule out the controller

    Make sure the zone is turned on and that no schedule or app setting is closing it. With temperature-controlled zones, each zone's damper closes as that zone reaches its set temperature, so a quiet zone may simply be satisfied. Raise or lower its set point and listen for a change at the outlets. If each zone has its own sensor, check it isn't sitting in sunlight, above a heater or next to an outlet.

    If the controller shows a fault for that zone, or the zone won't respond at all, note what it says. A controller that was reset by a power outage may need its zones set up again.

    Damper motors and cables

    Each zone has a damper in the duct, opened and closed by a small motor. Those motors live in a roof space that swings from near freezing on July nights to baking in January, and they wear out. A failed motor can leave the damper stuck closed, so the zone gets nothing, or stuck open, so it can't be turned off. The cable to the motor can also be crushed or pulled loose by anyone working in the roof.

    A disconnected or crushed duct

    If the system is running and other zones work, but one or two outlets get little or no air, a duct may have come off its outlet or junction, or been flattened. The air ends up in the roof space instead of the room. Signs include a roof space that feels unusually hot or cold, a rushing sound near the manhole, or a jump in running costs. Ducts and damper motors are reached from the roof, so leave that to a technician.

    What you can safely do now

    • Check the zone is on, and look for schedules or app settings closing it.
    • Change the zone's set temperature and listen for air at its outlets.
    • Check the other outlets in that zone to see whether all of them or just one are affected.
    • Note any fault message on the controller.
    • Don't climb into the roof space to look at dampers or ducts.

    Services that can help

    Read more in our guides

    Related questions

    Sources for this answer

    1 source, with the date each was checked
    1. 1.Department of Energy, Environment and Climate Action (energy.vic.gov.au), page last updated 14/04/25: We recommend providing 1.1 to 1.4kW of heating output for every 10m² of your home covered by a ducted system, depending on the individual characteristics of your home. ... We recommend zones for your ducted system, as… Accessed 30 September 2026.

    General information for homes in Victoria. Every installation is different, so treat this as a starting point. Where this answer refers to Victorian safety or rental rules, the sources above have the current requirements.