    Switchboards & safety switches

    How do I tell which switch has tripped on my switchboard?

    Updated 9 October 2026

    The short answer
    Open the switchboard door and look along the rows of switches. Most will point the same way, usually up. A tripped device has its lever down or sitting in a middle position. Safety switches have a test button and 30mA printed on them; circuit breakers don't. Note which one dropped and its label, unplug what was running on it, then reset it once.

    Reading the levers

    On a modern board the devices sit in rows behind a hinged door. A tripped one stands out because its lever doesn't match its neighbours. Some brands drop the lever to a middle position rather than all the way off, and some have a small coloured window that changes when the device is off. Open the door only; never unscrew or lift off the panel behind it.

    Check the main switch as well, because if it's off, everything is off. If every device is on and part of the house is still dead, the problem may be the supply or a sub-board somewhere else, such as in a garage, extension or granny flat.

    Safety switch or breaker

    Which device tripped tells you what kind of fault it was. Energy Safe Victoria says a safety switch always has a test button and 30mA printed on it. It trips when current leaks to earth, often from a faulty appliance or moisture, and it usually covers several circuits, so a whole group of rooms goes dark. A circuit breaker has no test button and trips for an overload or a short on its own circuit. An RCBO does both jobs for one circuit and has a test button too.

    Resetting once, and what to note

    Before resetting, switch off or unplug what was running in the rooms that lost power. If the lever sits in the middle, push it fully down first, then up. If it stays on, plug things back in one at a time and watch for the trip. If it won't stay on, or trips again, leave it off. Energy Safe Victoria's advice is to call a licensed electrician if a safety switch won't reset.

    Write down the label, the time, the weather and what was running. Labels on older boards are often missing or wrong, so the rooms that actually lost power tell us more than the label does. If your labels don't match what goes off, we can test and relabel the circuits.

    What you can safely do now

    • Open the switchboard door only if the board is dry, cool and undamaged. Never remove covers.
    • Unplug or switch off what was running in the rooms that lost power.
    • Reset the tripped device once, pushing it fully off first if the lever sits in the middle.
    • If it trips again or won't reset, leave it off and call a licensed electrician.
    • If the board is hot, buzzing, wet or smells burnt, leave it alone, and get everyone out if there is smoke or fire.

    Services that can help

    Read more in our guides

    Related questions

    Sources for this answer

    2 sources, with the date each was checked
    1. 1.Energy Safe Victoria: monitors the flow of electricity through a circuit detects a problem that may pose a risk to personal safety turns the power off within 0.03 of a second always has a test button and '30ma' printed on them. Accessed 30 September 2026.
    2. 2.Energy Safe Victoria: Locate your electricity box outside your home and check whether the safety switch has tripped. If it has tripped, reset the switch. If the switch won’t reset, call a licensed electrician. Accessed 30 September 2026.

    General information for homes in Victoria. Every installation is different, so treat this as a starting point. Where this answer refers to Victorian safety or rental rules, the sources above have the current requirements.