Skip to content
    • Licensed electrical contractor (REC 38187)
    • Lifetime workmanship guarantee
    • Upfront pricing: you get the price before we start
    • 4.9 from 34 Google reviews
    • Family-run, 19 years in the industry
    • Free, no-obligation quotes
    • Based in Altona Meadows, serving Melbourne's west
    • One local team for electrical, heating and cooling
    • Open Mon–Sat, 7am–5:30pm
    Quick questionnaire

    Is my switchboard due for an upgrade?

    Five quick questions, answered by looking, not touching. You'll see whether your board sounds fine, worth a check or due for replacement, and what to do next.

    Question 1 of 5

    Have you noticed any of these?

    At the switchboard or anywhere in the house.

    Every possible result

    All the answers this questionnaire can give, in one list, for anyone who would rather read than click.

    Have the switchboard looked at soon

    If there is smoke or fire, get everyone out of the house first. Otherwise, switch off at the main switch only if you can reach it without touching anything hot, wet or damaged, and keep everyone clear of the board.

    Heat, scorching, buzzing or a burning smell at a switchboard usually means a loose or overloaded connection. Don't wait for a planned upgrade.

    What it means

    • A connection that runs hot gets worse over time, until a breaker fails or the plastic around it scorches.
    • The fix might be a repair at the board, or the sign that the whole board is due for replacement.

    What we check before we price it

    • Connections and devices for heat damage
    • Which circuit is affected, and what was running on it
    • Whether the board can be repaired or should be replaced

    Ask your rental provider to have it checked

    In a rental, the rental provider arranges and pays for switchboard work, and Victorian rentals must already have a modern board with safety switches.

    What it means

    • Since 29 March 2023, Victorian rental properties must have modern switchboards with circuit breakers and safety switches.
    • The rental provider must organise and pay for repairs unless the renter caused the problem.
    • Put your request in writing to the rental provider or agent, and keep a copy.

    What we check before we price it

    • Whether the board meets the rental minimum standard
    • Any defects found during a rental electrical safety check

    An old fuse board is due for replacement

    Ceramic fuses mean an old board. Replacing it brings circuit breakers and safety switches on every circuit.

    What it means

    • When a switchboard is replaced, the Wiring Rules require safety switches on all final sub-circuits.
    • The power can't go back on to a new main switchboard until a Licensed Electrical Inspector has inspected it, so the inspection is planned into the job.
    • Older boards and their backing panels can contain asbestos. Don't drill, clean or break them.

    What we check before we price it

    • The board, the backing panel and the meter box
    • Every circuit, so each one can be tested and labelled
    • Room for future circuits such as air conditioning or an EV charger

    Some circuits may not have a safety switch

    A board with breakers but only one or two safety switches, or none, often leaves circuits unprotected. That's worth fixing.

    What it means

    • A safety switch turns the power off within 0.03 of a second when it detects a problem that may put people at risk.
    • The Wiring Rules require every final sub-circuit in a home to be protected by a safety switch, including the hot water circuit.
    • Sometimes safety switches can be added to the existing board; sometimes a new board is the better job.

    What we check before we price it

    • Which circuits each safety switch covers
    • Space and condition of the existing board
    • Whether RCBOs, one per circuit, suit your board

    Find out why it trips first

    Frequent tripping is a symptom. Finding the cause comes before any decision about upgrading the board.

    What it means

    • A safety switch that trips is usually doing its job: something on the circuit is leaking current, often an appliance or a wet outdoor fitting.
    • Reset a tripped safety switch once. If it trips again or won't reset, leave it off.

    What we check before we price it

    • Each circuit, tested to find where the fault is
    • Appliances, disconnected one at a time
    • The breakers and safety switches themselves

    Check the board before the new work

    Your board sounds modern, but new circuits for big appliances or a renovation are the moment to check its room and protection.

    What it means

    • The Wiring Rules require additional safety switch protection when an existing installation is altered.
    • Planning the board with the new work means one shutdown, not two.
    • Big loads like air conditioning, induction and EV charging may also need a look at the supply to the house.

    What we check before we price it

    • Spare room on the board for new circuits
    • What already runs on the supply, and what's being added
    • Safety switch protection for the circuits being altered

    An electrical safety check will tell you

    If you can't tell what's in the board, a safety check gives you a clear answer and a list to act on.

    What it means

    • A safety check covers the switchboard, wiring, fittings and safety switches.
    • A photo of the board with the door open and the covers left on is a good start for your enquiry.

    What we check before we price it

    • The switchboard, its protection and its labels
    • Wiring condition and the age of the installation
    • Safety switch trip tests

    Your board sounds fine. Keep the rental checks up to date

    A modern board with safety switches meets the rental standard. The two-yearly electrical safety check is the next thing to keep on track.

    What it means

    • Since 29 March 2023, rentals must have modern switchboards with circuit breakers and safety switches.
    • From 13 October 2026, gas and electrical safety checks every two years apply to all rental agreements, whatever date they started.
    • The electrician should give you a record of the check, including the results and any repairs needed.

    What we check before we price it

    • Switchboards, wiring and fittings, as the rental check requires
    • Safety switch trip tests
    • Any defects to repair

    Your board sounds fine for now

    Breakers, safety switches and no warning signs: keep testing the safety switches and have it looked at when your plans change.

    What it means

    • Energy Safe Victoria says to press the test button on each safety switch every three months. It should trip and cut the power.
    • If lights or appliances don't lose power when you press it, the safety switch may have failed and needs a licensed electrician.

    What we check before we price it

    • Safety switch trip times, measured with a tester
    • Connections and labels, if you'd like a maintenance check

    Opening the hinged door to look is fine. Leave every cover, screw and panel in place: parts behind them stay live. If the board is wet, scorched, buzzing or smells hot, don't open it at all.

    Sources for the rules on this page

    12 sources, with the date each was checked
    1. 1.Consumer Affairs Victoria: The electrical safety rental minimum standard commenced on 29 March 2023. Rental properties must have modern switchboards, with circuit breakers and electrical safety switches installed. Electrical safety switches are… Accessed 30 September 2026.
    2. 2.Consumer Affairs Victoria: The rental provider must organise and pay for all repairs if they are not the renter’s fault. Accessed 30 September 2026.
    3. 3.Energy Safe Victoria: If a switchboard is required to be replaced then as per clause 2.6.3.2.5 (Alterations to installations and replacement of switchboards) of AS/NZS 3000: RCD’s are required on all final sub-circuits. Accessed 30 September 2026.
    4. 4.Energy Safe Victoria: The electrician has eight business days after the work is completed to have that work inspected by a licensed electrical inspector (LEI). If an electrician replaces a main switchboard at a property, power cannot go back… Accessed 30 September 2026.
    5. 5.WorkSafe Victoria: A person who has management or control of a workplace, and employers or self-employed persons and employees should be aware of the typical uses and applications of ACMs, particularly in buildings constructed or… Accessed 30 September 2026.
    6. 6.Energy Safe Victoria: monitors the flow of electricity through a circuit detects a problem that may pose a risk to personal safety turns the power off within 0.03 of a second always has a test button and '30ma' printed on them. Accessed 30 September 2026.
    7. 7.Energy Safe Victoria: Clause 2.6.3.2.2 requires all final sub-circuits in a domestic installation be protected by a residual current device (RCD). A hot water service is included in this requirement Accessed 30 September 2026.
    8. 8.Energy Safe Victoria: Locate your electricity box outside your home and check whether the safety switch has tripped. If it has tripped, reset the switch. If the switch won’t reset, call a licensed electrician. Accessed 30 September 2026.
    9. 9.Energy Safe Victoria: Clause 2.6.3.2.5 of the Wiring Rules states: Additional protection by RCDs shall be provided in existing electrical installations where alterations or a switchboard replacement is completed. Accessed 30 September 2026.
    10. 10.Consumer Affairs Victoria: Mandatory gas and electrical safety checks every 2 years for all rental properties Rental providers and their agents must arrange gas and electrical safety checks by a qualified tradesperson every 2 years for all… Accessed 30 September 2026.
    11. 11.Consumer Affairs Victoria: The electrician should provide a record of the electrical safety check, which must include: the name of the licensed or registered electrician who conducted the check and their licence or registration number the date… Accessed 30 September 2026.
    12. 12.Energy Safe Victoria: Follow these steps to check your safety switch every three months: Press in the test buttons on each safety switch which will cut the power and trip the switch into the off position. You may hear a clunking sound. If… Accessed 30 September 2026.

    Want a price for your home?

    Free, no-obligation quotes. We look at the job, then you get the price before we start.

    Licensed electrical contractor (REC 38187)