Skip to content
    • Licensed electrical contractor (REC 38187)
    • Lifetime workmanship guarantee
    • Upfront pricing: you get the price before we start
    • 4.9 from 34 Google reviews
    • Family-run, 19 years in the industry
    • Free, no-obligation quotes
    • Based in Altona Meadows, serving Melbourne's west
    • One local team for electrical, heating and cooling
    • Open Mon–Sat, 7am–5:30pm

    Heating & cooling

    Air conditioning in an apartment or unit: what to check first

    Where the outdoor unit can go, owners corporation approval, pipe and drain runs, power and noise: the checks that decide what works in an apartment.

    7 min readPublished 30 October 2026
    Quick answer
    • Most apartments and units can have air conditioning, usually a wall split system. The outdoor unit's location, approval, the pipe and drain route and the power supply decide what's possible.
    • Check the owners corporation rules and get any approval in writing before you book an installation.
    • A balcony outdoor unit needs room to breathe and somewhere for its water to go that isn't the balcony below.
    • Most split systems need their own circuit, and altering the installation can bring safety switch work with it.
    • Compare the outdoor noise rating on the energy label and keep the unit away from neighbours' bedroom windows.
    Daikin wall-mounted split system on a timber-lined wall under a corrugated iron ceiling

    What decides whether it can be done

    The simple answer: most apartments and units can have air conditioning, usually a wall split system, but four things decide what's possible. Where the outdoor unit can go, whether the owners corporation approves it, how the pipes and drain get from the indoor unit to the outdoor unit, and whether your switchboard can supply it. Check those before you choose a system.

    A split system has an indoor unit on the wall and an outdoor unit, joined by a pair of refrigerant pipes, a drain and a cable. In a freestanding house there's usually somewhere for the outdoor unit. In an apartment the choices narrow quickly, which is why the outdoor unit is the first question, not the last.

    Where the outdoor unit can go

    A balcony is the usual spot. The unit can sit on the floor on a pad or feet, or hang on a wall bracket to keep the floor clear. It needs the clearances the manufacturer sets behind, beside and in front of it, and clear air in front of the fan. On a small or enclosed balcony, a unit pushed into a corner breathes its own hot air in summer and its own cold air in winter, and can throttle back on the hottest afternoons.

    Some buildings have a roof, plant deck or services area set aside for outdoor units. That keeps balconies clear and quiet, but the pipe run is longer, the route passes through common areas and servicing means getting a key or a building manager. Ground-floor units and townhouses often have a courtyard or side path, which is the simplest of all.

    Avoid spots where the unit would sit right under a neighbour's window, block a fire exit or path, or be hard for a technician to reach safely later.

    Owners corporation approval

    In many apartment buildings, the outside walls, roof and shared spaces are common property, and the owners corporation's rules often say where outdoor units can go, what they must look like and who can drill through what. Many buildings ask owners to apply before installing air conditioning, especially when the unit will be visible from the street or work is needed outside the lot.

    Ask your owners corporation or building manager for the rules before you get quotes. Useful questions: Are there approved locations for outdoor units? Have other owners installed systems, and where? Are there conditions about pipe covers, colours, drains or noise? Is roof or plant room access available, and how is it booked?

    Get any approval in writing, and share it with whoever quotes the job, so the design matches what was approved.

    Pipe and drain runs

    The shortest, tidiest job puts the indoor unit on the wall the balcony shares, with the outdoor unit directly outside. The pipes, drain and cable go straight through the wall in one small penetration and are hidden in a cover. Concrete and masonry walls take more work to core through than timber framing, and the location of steel in a slab or wall can rule some spots out.

    Every indoor unit makes water when it cools, and in heating mode the outdoor unit drips as it defrosts. The indoor unit's drain has to fall all the way to a floor waste or balcony drain, or use a small condensate pump where it can't. Water dripping over the edge onto the balcony below is a common complaint, so plan where every drip lands.

    Longer pipe runs to a roof or plant area work, within the limits the manufacturer sets for length and height, and they usually travel through service risers or along the outside of the building in covers. That route is part of what the owners corporation will want to see.

    Power and the switchboard

    Most apartments have their own small switchboard inside the unit, with the main meters and supply equipment in a shared meter room. An air conditioner usually needs a circuit from your own board. Energy Safe Victoria says that if a manufacturer's specifications require a dedicated circuit or safety switch protection for the unit, those specifications must be followed.

    Older boards can be full. Energy Safe Victoria notes that the Wiring Rules require additional safety switch protection when an existing installation is altered, so adding the air conditioning circuit can mean adding a safety switch too. A photo of your switchboard with the cover closed helps whoever is quoting spot this early.

    Air conditioners with a compressor have a lockable isolating switch next to the outdoor unit. On a balcony it needs to be weatherproof and reachable. The electrical work comes with a Certificate of Electrical Safety.

    Noise and the neighbours

    In an apartment your outdoor unit is close to other people's windows, and a compressor note carries further at night. Split systems carry separate indoor and outdoor noise ratings on the Zoned Energy Rating Label, which helps when you compare models.

    Position matters as much as the rating. Keep the unit off a wall shared with a neighbour's bedroom where you can, mount it on vibration pads or a solid bracket, and keep it clear of the balcony glass, which can drum. A unit that is sized properly also runs more quietly than one working flat out.

    Which system suits an apartment

    A single wall split in the living area suits most one and two bedroom apartments. If several rooms need their own head but there's room for only one outdoor unit, a multi-head system runs two or more indoor units from one outdoor unit. Where there's no good wall space, a floor console under a window can work, and apartments with bulkheads or ceiling space can sometimes take a bulkhead unit.

    Think about heating as well as cooling. Victorians usually use more energy for heating than cooling, and reverse-cycle units move 3 to 5 units of heat for each unit of electricity, against about 1 for a standard electric heater. Melbourne is in the Cold zone of the Zoned Energy Rating Label, so read the Cold ratings when you compare models.

    • Owners corporation rules and any approval in writing
    • Photos of the balcony or outdoor spot, with measurements
    • Photo of your switchboard with the cover closed
    • Where the indoor unit could go, and what's behind that wall
    • Parking, lift bookings and building access for installation day

    Common questions

    Often, yes, especially when the outdoor unit is on common property, visible from outside or needs drilling through shared walls. Check your building's rules first and get approval in writing.

    Services in this guide

    Not sure what you need yet

    Answer a few quick questions about your home for a plain answer, what we check before we price the job and what to read next.

    All questionnaires

    Quick answers

    More in the Help centre

    From the blog

    More on the blog

    Sources for this guide

    8 sources, with the date each was checked
    1. 1.Energy Safe Victoria: This means that if the manufacturer’s specifications require an air conditioner to be installed on a dedicated circuit or protected by a residual current device then they must be adhered to. Accessed 30 September 2026.
    2. 2.Energy Safe Victoria: Clause 2.6.3.2.5 of the Wiring Rules states: Additional protection by RCDs shall be provided in existing electrical installations where alterations or a switchboard replacement is completed. Accessed 30 September 2026.
    3. 3.Access Canberra Electrical Inspections (ACT Government), Electrical Fact Sheet, updated September 2019: Air-conditioning and heat pump systems incorporating a compressor shall be provided with an isolating switch (lockable) in accordance with Clause 2.3.2.2, installed adjacent to but not on the unit, which isolates all… Accessed 30 September 2026.
    4. 4.Energy Safe Victoria: 'Prescribed' certificates are for electrical installation work that requires inspection by a Licensed Electrical inspector. This includes (but is not limited to): Consumer mains cables, main switchboard, meter box and… Accessed 30 September 2026.
    5. 5.Energy Rating (GEMS Regulator / DCCEEW): On the right of the label after the stars, is the estimated annual energy use or power input in kilowatt hours (kWh) displaying cooling in blue (top number) and heating in red for each climate zone. ... Products are… Accessed 30 September 2026.
    6. 6.Department of Energy, Environment and Climate Action (energy.vic.gov.au), page last updated 14/04/25: Victorians typically use more energy for heating than cooling, so look for a unit with a higher heating efficiency. Accessed 30 September 2026.
    7. 7.Energy Rating (GEMS Regulator / DCCEEW): Reverse cycle air conditioners are much more efficient at heating than standard electric heaters (bar heaters, convection, or radiant heaters). ... During the normal operating range in Australia for every unit of… Accessed 30 September 2026.
    8. 8.Commonwealth of Australia (2019), 'The new zoned energy rating label for air conditioners—What installers and retailers need to know', hosted on energyrating.gov.au: Melbourne is in a black ‘COLD’ area—read the black Cold ratings. Accessed 30 September 2026.

    Planning advice for homeowners. Installation requirements depend on the property and equipment. Where this guide refers to Victorian safety or rental rules, use the linked official guidance for the current requirements.

    Talk it through with us

    Tell us what is happening at your place. Free, no-obligation quotes, and you get the price before we start.

    Ask for a quote 03 9116 9050