Why frost forms
A heat pump water heater draws outside air across a coil, and refrigerant in that coil picks up the air's warmth and passes it into the tank. The coil sits several degrees below the air temperature. On cold, damp mornings, and Laverton averages a July minimum of 5.2°C, frost forms on the fins. The unit senses it and defrosts, usually for a few minutes, and may go quiet or stop its fan while it does.
Signs of a fault
Frost that turns into a solid block, ice on the pipes or the fan, or ice that stays all day points to a problem. Common causes are a defrost sensor or control fault, a fan that isn't running properly, blocked airflow around the unit, or low refrigerant from a leak. Lukewarm water, a unit that seems to run constantly or a higher power bill often show up at the same time, because the backup element is doing the heating.
Refrigerant doesn't get used up, so low refrigerant means a leak. Nobody is allowed to top up a system until it has been fully tested and every identified leak repaired.
Reducing frost and booking a repair
Running the timer through the warmer part of the day cuts frosting a lot, and keeping bins, plants and stored gear clear of the unit lets it breathe. If ice keeps building up, book a repair and mention whether the water is still hot. Our team tests the power, controls, sensors and fan. Refrigerant work needs a technician with a refrigerant handling licence.
What you can safely do now
- Leave light frost alone; the defrost cycle will clear it.
- Don't chip at ice or pour hot water over the coil, which can damage the fins.
- Keep bins, plants and stored gear clear of the unit.
- Move the timer to the warmer part of the day if your tariff allows.
Services that can help
Read more in our guides
Related questions
- Should my heat pump hot water run during the day or overnight?If you can choose, run it during the day.
- Why does my hot water run out faster than it used to?Usually something has changed in the tank or in how it's heated.
- Is it normal for my hot water system to drip from the valve?A little water from the relief valve drain while the tank is heating is normal, because water expands as it heats and the valve lets the extra out.
- Does my gas ducted heater have a filter I can clean?Many do.
Sources for this answer
3 sources, with the date each was checked
- 1.Bureau of Meteorology: Mean minimum temperature (°C) 14.0 14.4 12.7 10.0 7.8 5.9 5.2 5.7 6.8 8.4 10.3 12.2 9.5 81 1943 2026 Accessed 30 September 2026.
- 2.Australian Refrigeration Council (ARC), Fact Sheet 13 (ARC5225, 11/22): ‘Topping-up’ a system before the system has been fully tested and all identified leaks repaired by any individual is illegal. Accessed 30 September 2026.
- 3.Australian Refrigeration Council (ARC): A Refrigerant Handling Licence must be held by any person who carries out work in relation to refrigeration and air conditioning (RAC) equipment. Carrying out work in relation to RAC equipment means to do anything with… Accessed 30 September 2026.
General information for homes in Victoria. Every installation is different, so treat this as a starting point. Where this answer refers to Victorian safety or rental rules, the sources above have the current requirements.